Figure II-55 Draining and Air Venting Flatwork Ironer
Balanced Pressure Thermostatic Air Vent
Drain to Safe Place
Float & Thermostatic Steam Trap
Steam Beds
The steam traps are often located at one end for ease of maintenance, with long pipes connecting them to the drainage points. If steam-locking is a problem in these long pipes, then a Float / Thermostatic steam trap with a steam-lock release is the best selection. The beds should be air vented at points remote from the steam entry. Steam supply lines to ironers should be drained, ideally using a separator.
Sight Glass with Check Valve
Strainer
HOOK-UP DIAGRAMS
Gravity Return
Steam Main
Drain to Safe Place
Balanced Pressure Thermostatic Air Vent
Rotating Cylinder
Strainer
Air Reservoir
Float & Thermostatic Steam Trap with SLR feature
Figure II-56 System Units for Condensate Removal and Air Venting of Rotating Cylinders (for surface speeds below 800 FPM) The Spirax Sarco units (Strainers, Float & Thermostatic Steam Traps with SLR feature, Sight Glass, Air Reservoir with Air Vent) provides for the best drainage of condensate and non condensibles from rotating cylinders.
Sight Glass
Gravity Condensate Return