The Clayton Guide To Steam Generation.
TECHNICAL SPECIFICATIONS Sheet 1 - 10 to 185 BHP
E-10
E-15
E-20
E-26
E-40
SE-40 E-50
SE-50
E-60
SE-60
E-80
SE-80
E-100
SE-100 E-125
SE-125
E-185 SE-185
GENERATOR MODEL
UNIT
98
147
196
255
392
392
490
490
589
589
785
785
981
981
1226
1226
1815
1815
MAXIMUM LOAD FIRING STEPS
kW
NET OUTPUT
ON/OFF burner
%
50 / 100 50 / 100
50 / 100 50 / 100 50 / 100
50 / 100
50 / 100
50 / 100
50 / 100 50 / 100
50 / 100
50 / 100
50 / 100 50 / 100
157
235
313
407
626
626
783
783
939
939
1253
1253
1566
1566
1957
1957
2897
2897
EQUIVALENT MAXIMUM OUTPUT SATURATED STEAM (*)
kg/h barg
Up to 150 barg depending on model and application
NOMINAL OPERATING STEAM PRESSURE
(230/400/415/440 VAC - 50/60 Hz) STANDARD INSTALLED ELECTRICAL MOTOR POWER
0.37
0.37
0.55
0.55
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
4.2
4.2
5.5
5.5
WATER PUMP
kW
1.5
1.5
1.5
GAS 90 1.5
1.5
1.5
1.5
1.5
3
3
5.5
5.5
5.5
5.5
5.5
5.5
11
11
BLOWER
kW
GAS
GAS
FUEL TYPE: G(Gas) O (Light Oil)
G O G O G O % 94 93 91 92 92 92
G O G O 91 92 94 95 94 95 96 96
G O G O G O G O G O G O G O G O G O G O 91 91 94 94 92 93 95 96 92 93 95 96 91 92 94 95 90 91 94 94 94 93 95 95 95 95 97 97 95 95 97 97 94 95 96 97 94 94 96 96
COMBUSTION EFFICIENCY (**)
88 93
95 93
@ 100% STEP @ 50% STEP
ON/OFF burner
%
10.2
15.7 13.5
20.7 18.0
36.0 42.0
34.8 76.5 40.6
54.5 104 62.9
52.8 130 60.9
192 71.1 83.0
27.5 25 2030 80.4 68.9 235 1025 677 1345 1980 1980 2700 1300 1755 61
103.7
100.5
131.1
126.9
196.2
37.1 108 367 2225 2315 2935 1415 1885 2185 1350 25 400 1155 820 162.8 187.8
GAS - LCV 37000 kJ/Nm 3 Nm3/h LIGHT OIL - LCV 42700 kJ/kg kg/h
CONSUMPTION @ FULL LOAD
27.6
54.2
76.5 30.4 51.3
24 8.9
88.9 192
86.1 235
112.4
108.8
168.1
24
50
50
65
65 20 25 7.8
192
235
296
WATER CONTENT
FILLED
L L
4.5 9.1
4.5 9.1
5.1 14
5.1 13
7.8 20
30.4
25
33
47
47
61
47
61
84
(generator water/steam system) IN OPERATION
11
11
10.7
15.8
19.1
19.1
27.5
19.1
27.5
25.1
m²
HEATIING SURFACE
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
GAS PRESSURE REQUIRED @ INLET (**)
mbarg
1520 1325
1520 1325
1000 2320 1240 1570 1846
1345 1035 1070 2320 1240 1570 1846
1345 677 1725 1025 2405 1300 1725 1755 2030
1725 1725 2405 1300 1345 1755 2030
2030
1725 1725 2405 1300 1345 1025 325 1755 2030 677
1980 1980 2700 1300 1345 1755 2030 1025 325 677
2000 1910 2515 1415 1885 2185 1350 820 1155
gas
mm mm mm mm mm
LENGTH
1325
1325
1045 1325
1325
1520
1520
1980 1980 2700 1300 1755 1345 1025 325 677
oil
835 960
835 960
gas
HEIGHT WIDTH
1045
945
945
945
945
OVERALL GENERATOR DIMENSIONS (approx.)
925
oil
1470
1470
1890
1890
2150
2465
2150
2450
gas - oil
gas
kg kg
WEIGHT (empty)
390 500 375 650
390 500 375 650
650 465 515 450
650 465 515 450
305 180 930 630 660 1065
305 180 930 630 790 1065
305 180 930 630 660 1065
930 630 790
965
oil
1345
LENGTH WIDTH HEIGHT WEIGHT
mm mm mm
680
680
677
OVERALL PUMP SKID DIMENSIONS (approx.)
1065
1025
1025
1025
40
40
40
40
180
381 325
381 325
325
457 325
457 325
559 400
kg
202
202
202
202
305
457
457
457
457
559
GENERATOR STACK CONNECTION (outer diameter)
mm
NOTES (*) @ 1 bara (absolute) with feed water temperature of 100 °C (**) based on feed water temperature of 60 °C (***) to be regulated by customer, based on 100% capacity and GAS-LCV as shown above.