Clayton-Power-Plant-Presentation
BLOWDOWN TANKS
IN COMPLIANCE WITH PM60 FROM THE UK HEALTH & SAFETY EXECUTIVE
The Clayton Blowdown Tank is designed to safely handle the discharges from the automatic blowdown on the Clayton Steam Generator. Water is collected in the sump of the vessel so that it cools naturally. Any additional water entering the tank replaces this standing water, which overflows into the outlet. If required, a thermostatically controlled forced cooling system can be provided which will reduce the water temperature to around 40 O C. This system is particularly useful when several boilers are connected to the same tank.
Designed to PD5500:2000 Cat 3 (Lloyds inspected) PED compliant. Design pressure 7 barg. Design Temperature 171 Deg C. Material BS1501-151 Grade 430A
H
G
E
K
135286UK 135287UK135288UK135294UK 135301UK
Standing Water (L) Vessel Volume (L)
25 50
40 80
90
200 400
350 700
180
30°
30°
Dimensions A (mm)
F
305
305
457
610
762
B (mm) C (mm) D (mm) E (mm)
1100
1500
1595
1845 1025 1275
2085 1150 1450
625 750 120
825
900
1050
1100
120
175
235
290
F (Dia) (mm)
15
15
15
15
15
G (mm)
220*
220*
308*
385*
475*
N
*approximate Connections H (Inlet)
A
H
1” BSP 100NB PN16 2” BSP
1” BSP 1 ¼” BSP 1 ½” BSP 2” BSP
K
100NB PN16 2” BSP
125NB PN16 2” BSP
150NB PN16 2” BSP
200NB PN16 2” BSP ¾” BSP 1” BSP 200NB PN16
I (Vent)
B
J (Cleanout) K (Outlet)
M L
1½” BSP 1½” BSP 2” BSP
2” BSP 80NB PN16
L (Cooling Water ) ¾” BSP ¾” BSP ¾” BSP ¾” BSP
D
M (Temp Sensor) N (Press Gauge)
1” BSP
1” BSP
1” BSP
1” BSP
C
3/8” BSP 3/8” BSP 3/8” BSP 3/8” BSP 3/8” BSP
Inspection Opening
150NB PN16
150NB PN16
2” BSP
2” BSP
J
www.claytonindustries.com
Made with FlippingBook - Online catalogs