Clayton Industries Corporate Brochure
publicación interactiva
Steam Generators Advanced Steam Boiler Technology that Is Safe, Efficient and Reliable
SAVES FUEL SAVES SPACE SAVES TIME SAVES MONEY
Advanced boiler technology for all steam applications, with many benefits
COMPACT, HIGHLY EFFICIENT, QUICK-STARTING STEAM GENERATOR SYSTEMS
COMPACT SIZE Smaller size means a smaller
RESPONSIVE Very rapid response to changing steam loads means the Clayton Steam Generator will automatically modulate to match your steam load profile while maintaining system steam pressure. SAFE Our once-through design eliminates the possibility of a steam or water- side explosion. The Clayton Steam Generator is simply the safest steam boiler available on the market.
LESS WATER WASTE Clayton’s design concentrates TDS blowdown significantly, reducing fuel, water and chemical costs. FAST START Full steam pressure and output in minutes from a cold startup saves fuel and labor cost over conventional designs and eliminates wasted fuel from idling.
AUTOMATIC Operation is automatically
RELIABLE Field proven reliability of the Clayton Steam Generator is unsurpassed, resulting in greatly reduced operator maintenance and attendance. QUALITY Steam quality in excess of 99.5% dryness is assured at all times. This is the highest steam quality of any competitor’s design. Less water and impurities further increase your energy efficiency.
space requirement. Clayton Steam Generators generally fit into any available area, reducing construction costs on new building installations. FUEL EFFICIENT Clayton’s high efficiency design translates into lower operating costs and improved overall system operation.
controlled. The Clayton Steam Generator can be started from a single switch or remotely using the automatic start option. LOW WEIGHT Its relatively light weight means that all sizes of Clayton Steam Generators can be easily moved and installed; even in areas with limited structural support.
Advanced boiler technology of the Clayton steam generator
COMPACT, HIGHLY EFFICIENT, QUICK-STARTING STEAM GENERATOR SYSTEMS
THE CLAYTON PUMP
THE CLAYTON PUMP | THE CLAYTON COIL | THE CLAYTON SEPARATOR
FEATURES
THE CLAYTON COIL The Clayton Pump has been designed specifically for the continuous supply of high-pressure and high-temperature feedwater to the Clayton Steam Generator and has exceptional durability. The pump does not have any glands or mechanical seals and the moving parts are semi-submerged in an oil reservoir. Faultless operation is achieved by the use of a reciprocating piston that pushes oil against a diaphragm that, in turn, moves water in a vertical column. The water inlet and outlet is at the top of the column so that heat from the water being pumped does not reach the pump mechanism. The complete assembly is housed in an extremely strong cast ductile iron block. The Clayton Pump is unsurpassed for long life, reliability and performance. The Clayton Coil has been developed for high heat transfer and long-term reliability. Its unique design allows water and heat to flow in opposite directions in a single pass. This counterflow pattern is the most efficient way to transfer heat energy and provides preheating of the incoming water. Each coil layer is carefully staggered, compared to the next. The spacing between each layer is varied so a constant high velocity is maintained as the flue gas density changes with temperature. The diameter of the tube also becomes larger as the water temperature increases and steam is produced. In the lower section, the coil forms a water wall around the combustion chamber that minimizes external heat loss. The result is fast heat transfer, even heat distribution and no hot spots. Mechanically, the coil acts like a spring to eliminate the effects of expansion. This allows Clayton Steam Generators to be started and stopped as frequently and as quickly as required without the possibility of mechanical damage. The Clayton Coil is the heart of the Clayton Steam Generator and has benefits that are not available with any other boiler. The Clayton Separator guarantees high-quality steam by combining cyclone separation and screen mist removal. The Separator operates in conjunction with the Clayton forced flow principle to guarantee steam quality of at least 99.5% dry saturated under all load conditions. The separator does not have any moving parts and no maintenance is required. A series of vanes produce a vortex flow pattern that removes water particles by centrifugal action. The separated droplets are collected and recycled. Impurities are simultaneously separated and can be removed by automatically blowing down a very small quantity of the collected water. No other blowdown is required and the total dissolved solids in the incoming water can be as high as 8,550 ppm. The Clayton Separator produces high-quality steam that is the best available from any type of boiler. THE CLAYTON SEPARATOR
The many advantages of using the Clayton Steam Generator is the result of combining three unique and proven technologies.
CLAYTON COIL l Counter Flow Heat Exchanger l No Refractory Insulation l Small Steel Mass l Low Heat Loss l Single Pass Heating l Upfired Burner l Rapid Heat Transfer
CLAYTON COIL
l
STEAM
CLAYTON PUMP
CLAYTON PUMP l Small Water Content l Pre-Heated Water l Controlled Water Flow CLAYTON SEPARATOR l Vortex Action l No Moving Parts l Automatic Blowdown
l
WATER
l
CLAYTON SEPARATOR
To produce steam in a Clayton Steam Generator, water goes in one end and high-quality steam comes out the other. The boiler feed water is pumped through the helical water tube coil from the top to the bottom while heat is passed over the coil in the opposite direction. The high efficiency separator at the outlet of the coil ensures that the steam is dry saturated. The principle of forced circulation of water using the Clayton Pump, Coil and Separator is the basis for the many benefits of using the Clayton Steam Generator.
HIGH PRESSURE COMBUSTION AIR BLOWER
AIR/FUEL MIXER
AIR/FUEL DAMPER CONTROL
To meet increasing demands for cleaner technologies, Clayton has created an advanced ultra low NOx burner system available on all our gas-fired steam generator units. The FMB (Fiber Metal Burner) technology achieves ultra low emissions through a combination of improved fuel and air mixing and very low, short flame length. This proven system is automatically controlled and capable of meeting strict local air emissions standards. LOW NOx TECHNOLOGY
FMB CONE BURNER
GASFLOW CONTROL VALVE
PILOT AIR PILOT FUEL
MAIN GASLINE
Used by the world’s leading companies
COMPACT, HIGHLY EFFICIENT, QUICK-STARTING STEAM GENERATOR SYSTEMS
SKID MOUNTED SYSTEMS
MODELS UP TO 2,000 BHP WITH DESIGN PRESSURES UP TO 3,000 PSIG SATURATED AND SUPERHEATED STEAM
CONTAINERIZED UNITS
EXHAUST GAS BOILERS
OFFSHORE / MARINE
COMPACT, HIGHLY EFFICIENT, QUICK-STARTING STEAM GENERATOR SYSTEMS
WORLDWIDE SALES & SERVICE Clayton Industries services the world with major manufacturing facilities in the USA, Europe, Latin America, and Asia. Clayton direct sales and service offices, subsidiary companies and authorized distributors are located worldwide offering lifetime customer support 24/7. World Headquarters 17477 Hurley Street City of Industry, CA, USA 91744 Tel: (800) 423-4585 sales@claytonindustries.com www.claytonindustries.com Canada 13 Edvac Drive, Unit 19 Brampton, Ontario Canada L6S 5W6 Tel: (905) 791-3322 canada@claytonindustries.com www.claytonindustries.com Europe, Africa, and Middle East Headquarters Rijksweg 30 Manuel L. Stampa 54 Nueva Industrial Vallejo Mexico D.F., 07700, Mexico Tel: (800) 888-4422 claytonmexico@clayton.com.mx clayton.com.mx Asia Headquarters 309 of Avenue 19 Economical and Technological Development Zone Hangzhou, China 310018 Tel: +0571 867598720 / 86092891 Info@kldco.net paul.lamberts@claytonindustries.com www.kldco.net 2880 Bornem, Belgium Tel: +32 (0)3 890 57 00 sales@clayton.be www.clayton.be Latin America Headquarters
The Clayton Story In 1930, Clayton Industries was formed in California by five engineers who were involved in the investigation and development of new concepts in thermodynamics pertaining to mechanical products. Fuel conservation was always a concern toWilliam Clayton, founder of Clayton Industries, long before modern-day awareness of dwindling fuel resources through our energy use. The Clayton Steam Generator evolved as a method to efficiently produce steam that is based on forced circulation of water. It was an immediate success and was being mass produced with thousands of units in daily operation by the 1940s. To meet a worldwide demand, Clayton Industries rapidly expanded overseas with purpose- built factories, licensed agreements, subsidiary companies and affiliates; while remaining a privately-owned company. Technological advancements continued throughout the years and models with larger outputs are continually being added to Clayton’s highly-respected product line. Since its inception, all of Clayton’s customers have remained loyal patrons.
WORLDWIDE HEADQUARTERS
Clayton Belgium
Clayton Mexico City
Headquarters, City of Industry, CA
Clayton Maquiladora
Clayton China
OUR WEBSITES:
USA: www.claytonindustries.com CANADA: www.claytonindustries.com
MEXICO: clayton.com.mx
GERMANY: www.clayton-deutschland.de
SPAIN: www.clayton.es HOLLAND: www.clayton.nl CHINA: www.kldco.net
BELGIUM: www.clayton.be FRANCE: www.clayton.fr
UK: www.claytonindustries.co.uk
www.claytonindustries.com (800) 423-4585
K-2014 – 9/14
PLC
PROGRAMMABLE LOGIC CONTROLLER
CLAYTON COMPUSTEAM PLC
Clayton Industries’ PLC-based steam systems incorporate the latest technology in boiler controls and provide instant touch access to operating control and information.
• INCREASED MACHINE RELIABILITY: Solid state technology eliminate the need for mechanical relays and timers. • DIRECT COMMUNICATION: Enables boiler room and plant control system linking. • MULTI-UNIT CONTROLS: Allows for control sequencing in a multi-unit installation. • MODBUS, ETHERNET/IP, AND BACNET PROTOCOL COMPATIBILITY • 10 inch touchscreen upgrade option available for most machines
Reliable
COMPUSTEAM PLC – I, II, and III Clayton Compusteam PLC Control Systems, which are standard on all modulating models, are available in three basic levels, I, II, & III, with a variety of options for expanding the capabilities beyond the basic systems. When operating, the PLC systems provide increased reliability. Operating parameters are readily available, on the Operator Interface Unit (OIU) displays and for remote data acquisition and control purposes. PLC interface capability also lends itself to improved communications between the Steam Generator controls and total plant monitoring systems. PLC based controls also provide enhanced control for multiple unit installations.
LEVEL I FUNCTIONS: Firing Rate, Steam Pressure, Pressure Set Points, Run Hours, Coil Tube Temperature LEVEL II FUNCTIONS: All Level I functions plus: Exhaust Gas Temperature, Feedwater Supply Pressure and Temperature LEVEL III FUNCTIONS: All Level II functions plus: Steam and Gas Flow Metering
OPTIONAL FEATURES: • Remote Start/Stop
• Remote Pressure Set Point • Ethernet Communications • MODBUS/BACnet • Automatic Start/Stop Sequencing of Multi-unit Installations
WORLD HEADQUARTERS 17477 Hurley Street City of Industry, CA 91744 TEL: 800-423-4585 FAX: 626-435-0180 Email: sales@claytonindustries.com www.claytonindustries.com
CANADA Clayton Sales & Service
LATIN AMERICA Clayton de Mexico, S.A. de C.V. Manuel L. Stampa 54 Nueva Industrial Vallejo Mexico D.F., 07700, Mexico TEL: +52 (55) 5586 5100 Email: claytonmexico@clayton.com.mx www.clayton.com.mx
ASIA PACIFIC/AUSTRALIA/ NEW ZEALAND Clayton Asia Pacific P.O. Box 620 Mt. Ommaney, Qld 4074, Australia TEL: +61-447 344 708 Email: neville.smith@claytonindustries.com
EUROPE/MIDDLE EAST/AFRICA Clayton of Belgium NV Rijksweg 30
910 Roundtree Dairy Rd., Unit 32 Vaughan, ONT, Canada L4L-5W6 TEL: 905-791-3322 FAX: 905-790-0583 Email: canada@claytonindustries.com 2880 Bornem, Belgium TEL: +32 (0)3 890 57 00 FAX: +32 (0)3 890 57 01 Email: sales@clayton.be www.clayton.be WORLD LEADER IN PRECISION STEAM GENERATORS, FLUID HEATERS, HEAT RECOVERY SYSTEMS, AND CUSTOMER SERVICE
Specifications Advanced Steam Boiler Technology that is Safe, Efficient and Reliable
S A V E S F U E L * S A V E S S P A C E * S A V E S T I M E * S A V E S M O N E Y
MODEL E154 STEAM GENERATOR 150 BHP
CLAYTON STEAM GENERATORS OFFER:
COMPACT SIZE Clayton steam generators will normally fit in any available area while also reducing construction costs on new building installations. FUEL EFFICIENT High efficiency which is inherent with the clayton design translates into lower operating costs and improved overall system operation RESPONSIVE Very rapid response to changing steam loads. Clayton steam generator will automatically modulate to match your steam load profile while maintaining system steam pressure SAFE Our once through design eliminates the possibility of a steam or water side explosion. The Clayton steam generator is simply the safest steam boiler on the market. LESS WATER WASTE Clayton’s design concentrates TDS blow down significantly which reduces wasted fuel, water and chemical costs. FAST START Full steam pressure and output in minutes from a cold start- up saves fuel and labor cost over conventional designs. Eliminates wasted fuel from idling. AUTOMATIC Operation is automatically controlled and the Clayton steam generator can be started from a single switch or remotely using an automatic start option. LOW WEIGHT The relatively light weight means that all sizes of Clayton steam generators can be easily moved and installed even in areas with limited structural support. RELIABLE Reliability of the Clayton steam generator is field proven and unsurpassed. This results in greatly reduced mainte- nance and attendance. HIGH QUALITY STEAM Steam Quality in excess of 99.5% dry is assured at all times. This is the highest steam quality of any competitive design. Less water and impurities further increase your energy effi- ciency .
MODEL E154
with Low NOx FMB Burner MODEL SEG154-FMB
MODEL E154
MODEL SE154
MODEL EG154-FMB
Standard
with Super Economizer with Low NOx FMB Burner and Super Economizer
150
150
NA 150
NA 150
BOILER HORSEPOWER HEAT INPUT, BTU/hr
5,021,250 6,123,476 6,049,699
5,907,353 5,021,250 5,838,663
Oil Gas
6,199,074 5,021,250
5,907,353 5,021,250
NET HEAT OUTPUT, BTU/hr EQUIVALENT OUTPUT (from and at 212°F feedwater and 0 PSIG steam) DESIGN PRESSURE (see note 1) STEAM OPERATING PRESSURE (determined by design pressure) OIL CONSUMPTION at maximum steam output (see note 2) GAS CONSUMPTION at maximum steam output (see note 3) BURNER CONTROLS modulating EFFICIENCY oil-fired efficiency % gas-fired efficiency % ELECTRIC MOTORS, HP (see note 4) ELECTRIC FLA, based on 460 V (see note 5) design pressure 15-300 psig design pressure 301-500 psig GAS SUPPLY PRESSURE REQUIRED ATOMIZING AIR REQUIRED (see note 6) Capacity Minimum pressure AIR SUPPLY REQUIRED (FMB - see note 7) WATER SUPPLY REQUIRED HEATING SURFACE EXHAUST STACK CONNECTION, o.d. APPROXIMATE OVERALL DIMENSIONS length width height WEIGHT installed - wet shipping FW pump skid design pressure 15-300 psig design pressure 301-500 psig
15 - 500 psig 5,175 lbs/hr 13 - 450 psig
15 - 500 psig 5,175 lbs/hr 13 - 450 psig
15 - 500 psig 5,175 lbs/hr 13 - 450 psig
15 - 500 psig 5,175 lbs/hr 13 - 450 psig
43.0 gph
41.5 gph
N/A
N/A
6,123 cfh
5,907 cfh
6,199 cfh
5,907 cfh
5 to 1 Turndown
5 to 1 Turndown
4 to 1 Turndown
4 to 1 Turndown
83% 82%
86% 85%
NA
NA
85% Blower Pump Cooling Blower Pump Cooling 81%
Blower
Pump Blower
Pump
7.5 7.5
5
5 5
7.5 7.5
5
5 5
7.5 7.5
5
7.5 7.5
5
7.5
7.5
7.5
7.5
24 28
24 28
32 35
35 35
5 to 10 psig
5 to 10 psig
5 to 10 psig
5 to 10 psig
473 sq.ft. 795 gph 70 psig 25 scfm N/A
25 scfm 70 psig
NA NA
NA NA
N/A
5 scfm @ 3 to 150 psig
610 sq. ft. 5 scfm @ 3 to 150 psig 795 gph
610 sq. ft. 795 gph
473 sq.ft. 795 gph
18 in.
18 in.
18 in.
18 in.
102 in. 93 in. 114 in.
121 in. 93 in. 114 in.
107 in. 113 in. 140 in.
850 lbs 8,560 lbs 9,811 lbs 124 ihn. 113 in. 140 in.
850 lbs 7,390 lbs 8,407 lbs
850 lbs 8,360 lbs 9,611 lbs
850 lbs 7,590 lbs 8,607 lbs
1) Design pressures are available up to 3000 psig. Consult factory for details. 2) Based on No. 2 fuel oil with a High Heat Value (HHV) of 140,600 BTU/Gal. 3) Based on Natural Gas with a High Heat Value (HHV) of 1,000 BTU/Ft.³ 4) Oil fired units also use a separate motor driven fuel oil pump - 1/3 HP 5) Continuous running. For 575 V multiply by 0.8; for 380 V multiply by 1.1; for 230 V multiply by 2.0; for 208 V multiply by 2.2.
6) Atomizing air required for oil burner. 7) Compressed air required for FMB.
The description and specifications shown were in effect at the time this publication was approved for printing. Clayton Industries, whose policy is one of continuous improvement, reserves the right to discontinue models, or change specifications or design, without notice.
G-E154-7/16
Specifications Advanced Steam Boiler Technology that is Safe, Efficient and Reliable
S A V E S F U E L * S A V E S S P A C E * S A V E S T I M E * S A V E S M O N E Y
MODEL E204 STEAM GENERATOR 200 BHP
CLAYTON STEAM GENERATORS OFFER:
COMPACT SIZE Clayton steam generators will normally fit in any available area while also reducing construction costs on new building installations. FUEL EFFICIENT High efficiency which is inherent with the clayton design translates into lower operating costs and improved overall system operation RESPONSIVE Very rapid response to changing steam loads. Clayton steam generator will automatically modulate to match your steam load profile while maintaining system steam pressure SAFE Our once through design eliminates the possibility of a steam or water side explosion. The Clayton steam generator is simply the safest steam boiler on the market. LESS WATER WASTE Clayton’s design concentrates TDS blow down significantly which reduces wasted fuel, water and chemical costs. FAST START Full steam pressure and output in minutes from a cold start- up saves fuel and labor cost over conventional designs. Eliminates wasted fuel from idling. AUTOMATIC Operation is automatically controlled and the Clayton steam generator can be started from a single switch or remotely using an automatic start option. LOW WEIGHT The relatively light weight means that all sizes of Clayton steam generators can be easily moved and installed even in areas with limited structural support. RELIABLE Reliability of the Clayton steam generator is field proven and unsurpassed. This results in greatly reduced mainte- nance and attendance. HIGH QUALITY STEAM Steam Quality in excess of 99.5% dry is assured at all times. This is the highest steam quality of any competitive design. Less water and impurities further increase your energy effi- ciency .
MODEL E204
and Super Economizer MODEL SEG204-FMB
MODEL E204
MODEL SE204
MODEL EG204-FMB with Low NOx Burner
Standard
with Super Economizer
with Low NOx Burner
BOILER HORSEPOWER HEAT INPUT, BTU/hr
200
200
NA 200
NA 200
Oil Gas
6,695,000 8,164,634 8,066,265
6,695,000 7,876,471 7,784,884
6,695,000 8,265,432
6,695,000 7,876,471
NET HEAT OUTPUT, BTU/hr EQUIVALENT OUTPUT (from and at 212°F feedwater and 0 PSIG steam) DESIGN PRESSURE (see note 1) STEAM OPERATING PRESSURE (determined by design pressure) OIL CONSUMPTION at maximum steam output (see note 2) GAS CONSUMPTION at maximum steam output (see note 3) BURNER CONTROLS modulating EFFICIENCY oil-fired efficiency % gas-fired efficiency % ELECTRIC MOTORS, HP (see note 4) ELECTRIC FLA, based on 460 V (see note 5) design pressure 15-300 psig design pressure 301-500 psig GAS SUPPLY PRESSURE REQUIRED ATOMIZING AIR REQUIRED (see note 6) Capacity Minimum pressure AIR SUPPLY REQUIRED (FMB -see note 7) WATER SUPPLY REQUIRED HEATING SURFACE EXHAUST STACK CONNECTION, o.d. APPROXIMATE OVERALL DIMENSIONS length width height WEIGHT installed - wet shipping FW pump skid design pressure 15-300 psig design pressure 301-500 psig
13 - 450 psig 15 - 500 psig 6,900 lbs/hr
13 - 450 psig 15 - 500 psig 6,900 lbs/hr
13 - 450 psig 15 - 500 psig 6,900 lbs/hr
13 - 450 psig 15 - 500 psig 6,900 lbs/hr
57.4 gph
55.4 gph
NA
NA
8,165 cfh
7,876 cfh
8,265 cfh
7,876 cfh
5 to 1 Turndown
5 to 1 Turndown
4 to 1 Turndown
4 to 1 Turndown
82% 83%
85% 86%
81% 85% Blower Pump Cooling Blower Pump Cooling NA NA
Blower
Pump Blower
Pump
10 10
10 7.5
5 5
10 10
10 7.5
5 5
10 10
7.5 10
10 10
7.5 10
35 32
35 32
42 39
42 39
5 to 10 psig
5 to 10 psig
5 to 10 psig
5 to 10 psig
25 scfm 70 psig
25 scfm 70 psig
NA 5 scfm @ 3 to 150 psig 5 scfm @ 3 to 150 psig NA NA NA
N/A
N/A
473 sq.ft. 1,060 gph
610 sq.ft. 1,060 gph
473 sq.ft. 1,060 gph
610 sq.ft. 1,060 gph
18 in.
18 in.
18 in.
18 in.
102 in. 93 in. 114 in.
121 in. 93 in. 114 in.
107 in. 113 in. 140 in.
124 in. 113 in. 140 in.
7,410 lbs 1,050 lbs 8,427 lbs
8,390 lbs 1,050 lbs 9,641 lbs
1,050 lbs 7,610 lbs 8,627 lbs
1,050 lbs 8,590 lbs 9,841 lbs
1) Design pressures are available up to 3000 psig. Consult factory for details. 2) Based on No. 2 fuel oil with a High Heat Value (HHV) of 140,600 BTU/Gal. 3) Based on Natural Gas with a High Heat Value (HHV) of 1,000 BTU/Ft.³ 4) Oil fired units also use a separate motor driven fuel oil pump - 1/3 HP 5) Continuous running. For 575 V multiply by 0.8; for 380 V multiply by 1.1; for 230 V multiply by 2.0; for 208 V multiply by 2.2.
6) Atomizing air required for oil burner. 7) Compressed air required for FMB.
The description and specifications shown were in effect at the time this publication was approved for printing. Clayton Industries, whose policy is one of continuous improvement, reserves the right to discontinue models, or change specifications or design, without notice.
G-E204-7/16
Specifications Advanced Steam Boiler Technology that is Safe, Efficient and Reliable
S A V E S F U E L * S A V E S S P A C E * S A V E S T I M E * S A V E S M O N E Y
MODEL E254 STEAM GENERATOR 250 BHP
CLAYTON STEAM GENERATORS OFFER:
COMPACT SIZE Clayton steam generators will normally fit in any available area while also reducing construction costs on new building installations. FUEL EFFICIENT High efficiency which is inherent with the clayton design translates into lower operating costs and improved overall system operation RESPONSIVE Very rapid response to changing steam loads. Clayton steam generator will automatically modulate to match your steam load profile while maintaining system steam pressure SAFE Our once through design eliminates the possibility of a steam or water side explosion. The Clayton steam generator is simply the safest steam boiler on the market. LESS WATER WASTE Clayton’s design concentrates TDS blow down significantly which reduces wasted fuel, water and chemical costs. FAST START Full steam pressure and output in minutes from a cold start- up saves fuel and labor cost over conventional designs. Eliminates wasted fuel from idling. AUTOMATIC Operation is automatically controlled and the Clayton steam generator can be started from a single switch or remotely using an automatic start option. LOW WEIGHT The relatively light weight means that all sizes of Clayton steam generators can be easily moved and installed even in areas with limited structural support. RELIABLE Reliability of the Clayton steam generator is field proven and unsurpassed. This results in greatly reduced mainte- nance and attendance. HIGH QUALITY STEAM Steam Quality in excess of 99.5% dry is assured at all times. This is the highest steam quality of any competitive design. Less water and impurities further increase your energy effi- ciency .
MODEL E254
MODEL SE254-FGR
250 with Flue Gas Recirculation
MODEL E254 MODEL SE254 MODEL E254-FGR
Standard
Super Econoith Flue Gas Recirculatio and Super Economizer
250
250
250
BOILER HORSEPOWER HEAT INPUT, BTU/hr
8,368,750 10,205,793 10,082,831
8,368,750 9,845,588 9,731,105
8,368,750 10,205,793 10,082,831
8,368,750 9,845,588 9,731,105
Oil Gas
NET HEAT OUTPUT, BTU/hr EQUIVALENT OUTPUT (from and at 212°F feedwater and 0 PSIG steam) DESIGN PRESSURE (see note 1) STEAM OPERATING PRESSURE (determined by design pressure) OIL CONSUMPTION at maximum steam output (see note 2) GAS CONSUMPTION at maximum steam output (see note 3) BURNER CONTROLS modulating EFFICIENCY oil-fired efficiency % gas-fired efficiency % ELECTRIC MOTORS, HP (see note 4) ELECTRIC FLA, based on 460 V (see note 5) design pressure 15-300 psig design pressure 301-500 psig GAS SUPPLY PRESSURE REQUIRED ATOMIZING AIR REQUIRED (see note 6) Capacity Minimum pressure AIR SUPPLY REQUIRED (FMB -see note 7) WATER SUPPLY REQUIRED HEATING SURFACE EXHAUST STACK CONNECTION, o.d. APPROXIMATE OVERALL DIMENSIONS length width height WEIGHT installed - wet shipping FW pump skid design pressure 15-300 psig design pressure 301-500 psig
8,625 lbs/hr
8,625 lbs/hr
8,625 lbs/hr
13 - 450 psig 15 - 500 psig 8,625 lbs/hr
13 - 450 psig 13 - 450 psig 13 - 450 psig 15 - 500 psig 15 - 500 psig 15 - 500 psig
71.7 gph
69.2 gph
71.7 gph
69.2 gph
10,206 cfh
9,846 cfh
10,206 cfh
9,846 cfh
5 to 1 Turndown to 1 Turndow 4 to 1 Turndown
4 to 1 Turndown
82% 83%
85% 86%
86% 85%
83% 82%
5 Cooling Blower Pump Cooling
Pump Blower
Blowe Pump
Blower
10 15 10 10
5 5
10 10
59 42 15 10
10 10
10 15
10 10 42 35
5
42 35
59 42
5 to 10 psig
5 to 10 psig
5 to 10 psig
5 to 10 psig
70 psig 25 scfm
70 psig 25 scfm
25 scfm 70 psig
25 scfm 70 psig
N/A
N/A
N/A
N/A
473 sq.ft. 1,325 gph
610 sq. ft. 1,325 gph
473 sq.ft. 1,325 gph
610 sq. ft. 1,325 gph
24 in.
24 in.
24 in.
24 in.
102 in. 104 in. 114 in.
120 in. 104 in. 114 in.
126 113 152
145 113 152
1,050 lbs 7,410 lbs 8,427 lbs
1,050 lbs 9,440 lbs 10,935 lbs
1,050 lbs 7,610 lbs 8,627 lbs
1,050 lbs 8,590 lbs 9,841 lbs
1) Design pressures are available up to 3000 psig. Consult factory for details. 2) Based on No. 2 fuel oil with a High Heat Value (HHV) of 140,600 BTU/Gal. 3) Based on Natural Gas with a High Heat Value (HHV) of 1,000 BTU/Ft.³ 4) Oil fired units also use a separate motor driven fuel oil pump - 1/2 HP 4) Continuous running. For 575 V multiply by 0.8; for 380 V multiply by 1.1; for 230 V multiply by 2.0; for 208 V multiply by 2.2.
5) Atomizing air required for oil burner. 6) Compressed air required for FMB.
The description and specifications shown were in effect at the time this publication was approved for printing. Clayton Industries, whos policy is one of continuous improvement, reserves the right to discontinue models, or change specifications or design, without notice.
G-E254FGR-7/16
Specifications Advanced Steam Boiler Technology that is Safe, Efficient and Reliable
S A V E S F U E L * S A V E S S P A C E * S A V E S T I M E * S A V E S M O N E Y
MODEL E304 STEAM GENERATOR 300 BHP
CLAYTON STEAM GENERATORS OFFER:
COMPACT SIZE Clayton steam generators will normally fit in any available area while also reducing construction costs on new building installations. FUEL EFFICIENT High efficiency which is inherent with the clayton design translates into lower operating costs and improved overall system operation RESPONSIVE Very rapid response to changing steam loads. Clayton steam generator will automatically modulate to match your steam load profile while maintaining system steam pressure SAFE Our once through design eliminates the possibility of a steam or water side explosion. The Clayton steam generator is simply the safest steam boiler on the market. LESS WATER WASTE Clayton’s design concentrates TDS blow down significantly which reduces wasted fuel, water and chemical costs. FAST START Full steam pressure and output in minutes from a cold start- up saves fuel and labor cost over conventional designs. Eliminates wasted fuel from idling. AUTOMATIC Operation is automatically controlled and the Clayton steam generator can be started from a single switch or remotely using an automatic start option. LOW WEIGHT The relatively light weight means that all sizes of Clayton steam generators can be easily moved and installed even in areas with limited structural support. RELIABLE Reliability of the Clayton steam generator is field proven and unsurpassed. This results in greatly reduced mainte- nance and attendance. HIGH QUALITY STEAM Steam Quality in excess of 99.5% dry is assured at all times. This is the highest steam quality of any competitive design. Less water and impurities further increase your energy effi- ciency .
MODEL E304
MODEL SE304-FMB
MODEL E304
MODEL SE304
MODEL EG304-FMB with Low NOx Burner
Standard
with Super Economizer
with Low NOx Burner
and Super Economizer
300
300
NA 300
NA 300
BOILER HORSEPOWER HEAT INPUT, BTU/hr
10,042,500 12,246,951 12,099,398
10,042,500 11,814,706 11,677,326
Oil Gas
10,042,500 12,398,148
10,042,500 11,814,706
NET HEAT OUTPUT, BTU/hr EQUIVALENT OUTPUT (from and at 212°F feedwater and 0 PSIG steam) DESIGN PRESSURE (see note 1) STEAM OPERATING PRESSURE (determined by design pressure) OIL CONSUMPTION at maximum steam output (see note 2) GAS CONSUMPTION at maximum steam output (see note 3) BURNER CONTROLS modulating EFFICIENCY ELECTRIC FLA, based on 460 V (see note 4) design pressure 15-300 psig design pressure 301-500 psig GAS SUPPLY PRESSURE REQUIRED ATOMIZING AIR REQUIRED (see note 5) Capacity Minimum pressure AIR SUPPLY REQUIRED (FMB -see note 6) WATER SUPPLY REQUIRED HEATING SURFACE EXHAUST STACK CONNECTION, o.d. APPROXIMATE OVERALL DIMENSIONS length width height WEIGHT installed - wet shipping FW pump skid oil-fired efficiency % gas-fired efficiency % ELECTRIC MOTORS, HP design pressure 15-300 psig design pressure 301-500 psig
13 - 450 psig 15 - 500 psig 10,350 lbs/hr
13 - 450 psig 15 - 500 psig 10,350 lbs/hr
13 - 450 psig 15 - 500 psig 10,350 lbs/hr
13 - 450 psig 15 - 500 psig 10,350 lbs/hr
86.1 gph
83.1 gph
N/A
N/A
12,247 cfh
11,815 cfh
12,398 cfh
11,815 cfh
5 to 1 Turndown
5 to 1 Turndown
4 to 1 Turndown
4 to 1 Turndown
82% 83%
85% 86%
81% NA
85% NA
30 5 Blower Pump Cooling Blower Pump Cooling
Blower
Pump Blower
Pump
82 75 10 15
5 5
30 30
82 75 15 10
15 15
10 15
15 15
10 15
30
5
51 44
51 44
5 to 10 psig
5 to 10 psig
5 to 10 psig
5 to 10 psig
25 scfm 70 psig
25 scfm 70 psig
NA
NA
5 scfm @ 3 to 150 psig 5 scfm @ 3 to 150 psig NA NA
N/A
N/A
594 sq.ft. 1,590 gph
796 sq.ft. 1,590 gph
594 sq.ft. 1,590 gph
796 sq.ft. 1,590 gph
24 in.
24 in.
24 in.
24 in.
114 in. 104 in. 114 in.
137 in. 104 in. 114 in.
121 in. 116 in. 160 in.
144 in. 116 in. 160 in.
1,150 lbs 9,140 lbs 10,566 lbs
1,150 lbs 10,530 lbs 12,297 lbs
1,150 lbs 9,340 lbs 10,766 lbs
1,150 lbs 10,730 lbs 12,497 lbs
1) Design pressures are available up to 3000 psig. Consult factory for details. 2) Based on No. 2 fuel oil with a High Heat Value (HHV) of 140,600 BTU/Gal. 3) Based on Natural Gas with a High Heat Value (HHV) of 1,000 BTU/Ft.³ 4) Continuous running. For 575 V multiply by 0.8; for 380 V multiply by 1.1; for 230 V multiply by 2.0; for 208 V multiply by 2.2.
5) Atomizing air required for oil burner. 6) Compressed air required for FMB.
The description and specifications shown were in effect at the time this publication was approved for printing. Clayton Industries, whose policy is one of continuous improvement, reserves the right to discontinue models, or change specifications or design, without notice.
G-E304- 7/16
Specifications Advanced Steam Boiler Technology that is Safe, Efficient and Reliable
S A V E S F U E L * S A V E S S P A C E * S A V E S T I M E * S A V E S M O N E Y
MODEL E354 STEAM GENERATOR 350 BHP
CLAYTON STEAM GENERATORS OFFER:
COMPACT SIZE Clayton steam generators will normally fit in any available area while also reducing construction costs on new building installations. FUEL EFFICIENT High efficiency which is inherent with the clayton design translates into lower operating costs and improved overall system operation RESPONSIVE Very rapid response to changing steam loads. Clayton steam generator will automatically modulate to match your steam load profile while maintaining system steam pressure SAFE Our once through design eliminates the possibility of a steam or water side explosion. The Clayton steam generator is simply the safest steam boiler on the market. LESS WATER WASTE Clayton’s design concentrates TDS blow down significantly which reduces wasted fuel, water and chemical costs. FAST START Full steam pressure and output in minutes from a cold start- up saves fuel and labor cost over conventional designs. Eliminates wasted fuel from idling. AUTOMATIC Operation is automatically controlled and the Clayton steam generator can be started from a single switch or remotely using an automatic start option. LOW WEIGHT The relatively light weight means that all sizes of Clayton steam generators can be easily moved and installed even in areas with limited structural support. RELIABLE Reliability of the Clayton steam generator is field proven and unsurpassed. This results in greatly reduced mainte- nance and attendance. HIGH QUALITY STEAM Steam Quality in excess of 99.5% dry is assured at all times. This is the highest steam quality of any competitive design. Less water and impurities further increase your energy effi- ciency .
MODEL E354
MODEL SEG354-FMB
MODEL E354
MODEL SE354
MODEL EG354-FMB with Low NOx Burner
Standard
with Super Economizer
with Low NOx Burner
and Super Economizer
350
350
NA 350
NA 350
BOILER HORSEPOWER HEAT INPUT, BTU/hr
11,716,250 14,288,110 14,115,964
11,716,250 13,783,824 13,623,547
Oil Gas
11,716,250 14,464,506
11,716,250 13,783,824
NET HEAT OUTPUT, BTU/hr EQUIVALENT OUTPUT (from and at 212°F feedwater and 0 PSIG steam) DESIGN PRESSURE (see note 1) STEAM OPERATING PRESSURE (determined by design pressure) OIL CONSUMPTION at maximum steam output (see note 2) GAS CONSUMPTION at maximum steam output (see note 3) BURNER CONTROLS modulating EFFICIENCY oil-fired efficiency % gas-fired efficiency % ELECTRIC MOTORS, HP (see note 4) ELECTRIC FLA, based on 460 V (see note 5) design pressure 15-300 psig design pressure 301-500 psig GAS SUPPLY PRESSURE REQUIRED ATOMIZING AIR REQUIRED (see note 6) Capacity Minimum pressure AIR SUPPLY REQUIRED (FMB -see note 7) WATER SUPPLY REQUIRED HEATING SURFACE EXHAUST STACK CONNECTION, o.d. APPROXIMATE OVERALL DIMENSIONS length width height WEIGHT installed - wet shipping FW pump skid design pressure 15-300 psig design pressure 301-500 psig
13 - 450 psig 15 - 500 psig 12,075 lbs/hr
13 - 450 psig 15 - 500 psig 12,075 lbs/hr
13 - 450 psig 15 - 500 psig 12,075 lbs/hr
13 - 450 psig 15 - 500 psig 12,075 lbs/hr
100.4 gph
96.9 gph
N/A
N/A
14,288 cfh
13,784 cfh
14,465 cfh
13,784 cfh
5 to 1 Turndown
5 to 1 Turndown
4 to 1 Turndown
4 to 1 Turndown
82% 83%
85% 86%
81% NA
NA 85%
30 5 Blower Pump Cooling Blower Pump Cooling
Blower
Pump Blower
Pump
95 89 15 20
5 5
30 30
95 89 20 15
25 25
15 20
25 25
15 20
30
5
74 67
74 67
5 to 10 psig
5 to 10 psig
5 to 10 psig
5 to 10 psig
25 scfm 70 psig
NA NA
NA NA
70 psig 25 scfm
N/A
N/A
5 scfm @ 3 to 150 psig 5 scfm @ 3 to 150 psig
594 sq.ft. 1,855 gph
796 sq.ft. 1,855 gph
594 sq.ft. 1,855 gph
796 sq.ft. 1,855 gph
24 in.
24 in.
24 in.
24 in.
114 in. 104 in. 114 in.
137 in. 104 in. 114 in.
121 in. 116 in. 160 in.
144 in. 116 in. 160 in.
1,150 lbs 10,566 lbs 9,140 lbs
1,150 lbs 10,530 lbs 12,297 lbs
1,150 lbs 9,340 lbs 10,766 lbs
1,150 lbs 10,730 lbs 12,497 lbs
1) Design pressures are available up to 3000 psig. Consult factory for details. 2) Based on No. 2 fuel oil with a High Heat Value (HHV) of 140,600 BTU/Gal. 3) Based on Natural Gas with a High Heat Value (HHV) of 1,000 BTU/Ft.³ 4) Oil fired units also use a separate motor driven fuel oil pump - 1/2 HP 5) Continuous running. For 575 V multiply by 0.8; for 380 V multiply by 1.1; for 230 V multiply by 2.0; for 208 V multiply by 2.2.
6) Atomizing air required for oil burner. 7) Compressed air required for FMB.
The description and specifications shown were in effect at the time this publication was approved for printing. Clayton Industries, whose policy is one of continuous improvement, reserves the right to discontinue models, or change specifications or design, without notice.
G-E354-7/16
Specifications Advanced Steam Boiler Technology that is Safe, Efficient and Reliable
S A V E S F U E L * S A V E S S P A C E * S A V E S T I M E * S A V E S M O N E Y
MODEL E404 STEAM GENERATOR 400 BHP
CLAYTON STEAM GENERATORS OFFER:
COMPACT SIZE Clayton steam generators will normally fit in any available area while also reducing construction costs on new building installations. FUEL EFFICIENT High efficiency which is inherent with the clayton design translates into lower operating costs and improved overall system operation RESPONSIVE Very rapid response to changing steam loads. Clayton steam generator will automatically modulate to match your steam load profile while maintaining system steam pressure SAFE Our once through design eliminates the possibility of a steam or water side explosion. The Clayton steam generator is simply the safest steam boiler on the market. LESS WATER WASTE Clayton’s design concentrates TDS blow down significantly which reduces wasted fuel, water and chemical costs. FAST START Full steam pressure and output in minutes from a cold start- up saves fuel and labor cost over conventional designs. Eliminates wasted fuel from idling. AUTOMATIC Operation is automatically controlled and the Clayton steam generator can be started from a single switch or remotely using an automatic start option. LOW WEIGHT The relatively light weight means that all sizes of Clayton steam generators can be easily moved and installed even in areas with limited structural support. RELIABLE Reliability of the Clayton steam generator is field proven and unsurpassed. This results in greatly reduced mainte- nance and attendance. HIGH QUALITY STEAM Steam Quality in excess of 99.5% dry is assured at all times. This is the highest steam quality of any competitive design. Less water and impurities further increase your energy effi- ciency .
MODEL E404
and Super Economizer MODEL SEG404-FMB
Standard MODEL E404
MODEL SE404
MODEL EG404-FMB with Low NOx Burner
with Low NOx Burner
with Super Economizer
BOILER HORSEPOWER HEAT INPUT, BTU/hr
400
400
NA 400
NA 400
13,390,000 16,329,268 16,132,530
13,390,000 15,752,941 15,569,767
Oil Gas
13,390,000 16,530,864
13,390,000 15,752,941
NET HEAT OUTPUT, BTU/hr EQUIVALENT OUTPUT (from and at 212°F feedwater and 0 PSIG steam) DESIGN PRESSURE (see note 1) STEAM OPERATING PRESSURE (determined by design pressure) OIL CONSUMPTION at maximum steam output (see note 2) GAS CONSUMPTION at maximum steam output (see note 3) BURNER CONTROLS modulating EFFICIENCY oil-fired efficiency % gas-fired efficiency % ELECTRIC MOTORS, HP (see note 4) ELECTRIC FLA, based on 460 V (see note 5) design pressure 15-300 psig design pressure 301-500 psig GAS SUPPLY PRESSURE REQUIRED ATOMIZING AIR REQUIRED (see note 6) Capacity Minimum pressure AIR SUPPLY REQUIRED (FMB-see note 7) WATER SUPPLY REQUIRED HEATING SURFACE EXHAUST STACK CONNECTION, o.d. APPROXIMATE OVERALL DIMENSIONS length width height WEIGHT installed - wet shipping FW pump skid design pressure 15-300 psig design pressure 301-500 psig
60 - 450 PSIG 65 - 500 PSIG 13,800 lbs/hr
60 - 450 PSIG 65 - 500 PSIG 13,800 lbs/hr
60 - 450 PSIG 65 - 500 PSIG 13,800 lbs/hr
60 - 450 PSIG 65 - 500 PSIG 13,800 lbs/hr
114.7 gph
110.7 gph
N/A
N/A
16,329 cfh
15,753 cfh
16,531 cfh
15,753 cfh
5 to 1 Turndown
5 to 1 Turndown
4 to 1 Turndown
4 to 1 Turndown
82% 83%
85% 86%
81% NA
85% NA
Pump Blower
Pump
40 7.5 Blower Pump Cooling Blower Pump Cooling
Blower
25 25
20 20
25 25
20 20
92 92 20 20
7.5 7.5
40 40
92 92 20 20
40
7.5
74 74
74 74
5 to 10 psig
5 to 10 psig
5 to 10 psig
5 to 10 psig
70 psig 30 scfm
70 psig 30 scfm
NA
NA
NA NA 5 scfm @ 3 to 150 psig 5 scfm @ 3 to 150 psig
N/A
N/A
912 sq.ft. 2,120 gph
1,207 sq.ft. 2,120 gph
912 sq.ft. 2,120 gph
1,207 sq.ft. 2,120 gph
32 in.
32 in.
32 in.
32 in.
131 in. 131 in. 133 in.
157 in. 131 in. 133 in.
135 in. 142 in. 156 in.
161 in. 142 in. 156 in.
1,970 lbs 14,650 lbs 17,268 lbs
1,970 lbs 17,040 lbs 20,250 lbs
1,970 lbs 14,950 lbs 17,568 lbs
1,970 lbs 17,340 lbs 20,550 lbs
1) Design pressures are available up to 3000 psig. Consult factory for details. 2) Based on No. 2 fuel oil with a High Heat Value (HHV) of 140,600 BTU/Gal. 3) Based on Natural Gas with a High Heat Value (HHV) of 1,000 BTU/Ft.³ 4) Oil fired units also use a separate motor drivne fuel oil pump - 3/4 HP 5) Continuous running. For 575 V multiply by 0.8; for 380 V multiply by 1.1; for 230 V multiply by 2.0; for 208 V multiply by 2.2.
6) Atomizing air required for oil burner. 7) Compressed air required for FMB.
The description and specifications shown were in effect at the time this publication was approved for printing. Clayton Industries, whose policy is one of continuous improvement, reserves the right to discontinue models, or change specifications or design, without notice.
G-E404-7/16
Specifications Advanced Steam Boiler Technology that is Safe, Efficient and Reliable
S A V E S F U E L * S A V E S S P A C E * S A V E S T I M E * S A V E S M O N E Y
MODEL E504 STEAM GENERATOR 500 BHP
CLAYTON STEAM GENERATORS OFFER:
COMPACT SIZE Clayton steam generators will normally fit in any available area while also reducing construction costs on new building installations. FUEL EFFICIENT High efficiency which is inherent with the clayton design translates into lower operating costs and improved overall system operation RESPONSIVE Very rapid response to changing steam loads. Clayton steam generator will automatically modulate to match your steam load profile while maintaining system steam pressure SAFE Our once through design eliminates the possibility of a steam or water side explosion. The Clayton steam generator is simply the safest steam boiler on the market. LESS WATER WASTE Clayton’s design concentrates TDS blow down significantly which reduces wasted fuel, water and chemical costs. FAST START Full steam pressure and output in minutes from a cold start- up saves fuel and labor cost over conventional designs. Eliminates wasted fuel from idling. AUTOMATIC Operation is automatically controlled and the Clayton steam generator can be started from a single switch or remotely using an automatic start option. LOW WEIGHT The relatively light weight means that all sizes of Clayton steam generators can be easily moved and installed even in areas with limited structural support. RELIABLE Reliability of the Clayton steam generator is field proven and unsurpassed. This results in greatly reduced mainte- nance and attendance. HIGH QUALITY STEAM Steam Quality in excess of 99.5% dry is assured at all times. This is the highest steam quality of any competitive design. Less water and impurities further increase your energy effi- ciency .
MODEL E504
and Super Economizer MODEL SEG504-FMB
MODEL E504
MODEL SE504
MODEL EG504-FMB with Low NOx Burner
Standard
with Super Economizer
with Low NOx Burner
500
500
NA 500
NA 500
BOILER HORSEPOWER HEAT INPUT, BTU/hr
16,737,500 20,411,585 20,165,663
16,737,500 19,691,176 19,462,209
Oil Gas
16,737,500 20,663,580
16,737,500 19,691,176
NET HEAT OUTPUT, BTU/hr EQUIVALENT OUTPUT (from and at 212°F feedwater and 0 PSIG steam) DESIGN PRESSURE (see note 1) STEAM OPERATING PRESSURE (determined by design pressure) OIL CONSUMPTION at maximum steam output (see note 2) GAS CONSUMPTION at maximum steam output (see note 3) BURNER CONTROLS modulating EFFICIENCY oil-fired efficiency % gas-fired efficiency % ELECTRIC MOTORS, HP (see note 4) ELECTRIC FLA, based on 460 V (see note 5) design pressure 15-300 psig design pressure 301-500 psig GAS SUPPLY PRESSURE REQUIRED ATOMIZING AIR REQUIRED (see note 6) Capacity Minimum pressure AIR SUPPLY REQUIRED (FMB -see note 7) WATER SUPPLY REQUIRED HEATING SURFACE EXHAUST STACK CONNECTION, o.d. APPROXIMATE OVERALL DIMENSIONS length width height WEIGHT installed - wet shipping FW pump skid design pressure 15-300 psig design pressure 301-500 psig
60 - 450 PSIG 65 - 500 PSIG 17,250 lbs/hr
60 - 450 PSIG 65 - 500 PSIG 17,250 lbs/hr
60 - 450 PSIG 65 - 500 PSIG 17,250 lbs/hr
60 - 450 PSIG 65 - 500 PSIG 17,250 lbs/hr
143.4 gph
138.4 gph
N/A
N/A
20,412 cfh
19,691 cfh
20,664 cfh
19,691 cfh
5 to 1 Turndown
5 to 1 Turndown
4 to 1 Turndown
4 to 1 Turndown
82% 83%
85% 86%
81% NA
85% NA
30 7.5 Blower Pump Cooling Blower Pump Cooling
Blower
Pump Blower
Pump
20 30
7.5 7.5
30 30
30 20
25 25
20 30
25 25
20 30
30
7.5
85 74
85 74
92
92
107
107
5 to 10 psig
5 to 10 psig
5 to 10 psig
5 to 10 psig
70 psig 30 scfm
70 psig 30 scfm
NA
NA
NA NA 5 scfm @ 3 to 150 psig 5 scfm @ 3 to 150 psig
N/A
N/A
912 sq.ft. 2,650 gph
1,207 sq.ft. 2,650 gph
912 sq.ft. 2,650 gph
1,207 sq.ft. 2,650 gph
32 in.
32 in.
32 in.
32 in.
131 in. 131 in. 133 in.
157 in. 131 in. 133 in.
135 in. 142 in. 156 in.
161 in. 142 in. 156 in.
2,000 lbs 14,790 lbs 17,408 lbs
2,000 lbs 17,190 lbs 20,400 lbs
2,000 lbs 15,090 lbs 17,708 lbs
2,000 lbs 17,490 lbs 20,700 lbs
1) Design pressures are available up to 3000 psig. Consult factory for details. 2) Based on No. 2 fuel oil with a High Heat Value (HHV) of 140,600 BTU/Gal. 3) Based on Natural Gas with a High Heat Value (HHV) of 1,000 BTU/Ft.³ 4) Oil fired units also use a separate motor driven fuel oil pump - 3/4 HP 4) Continuous running. For 575 V multiply by 0.8; for 380 V multiply by 1.1; for 230 V multiply by 2.0; for 208 V multiply by 2.2.
5) Atomizing air required for oil burner. 6) Compressed air required for FMB.
The description and specifications shown were in effect at the time this publication was approved for printing. Clayton Industries, whose policy is one of continuous improvement, reserves the right to discontinue models, or change specifications or design, without notice.
G-E504-7/16